What was found
HYD 1 PUMP FAIL & HYD 1 LOW QTY IN FLIGHT. ELEC PUMP HELD AT 2900 PSI REMAINDER OF FLIGHT. UPON LANDING ELEC PUMP WENT TO 100 PSI & LOST STEERING. TRANSFERRED TO NRWC 694-ORD-02076. FROM NRWC 694-ORD-02076, REPLACED E1 HYD PUMP IAW AMM 29-10-03. REF ITEM'S 2 & 3 LOG PAGE 3922807 & ITEM NR 1 LOG PAGE 3922808 FOR REPLACEMENT OF E1 HYD HOSE & CARBON SEAL. R & R NR 1 ENG HYD HOSE & HYD PUMP IAW AMM 29-10-13.