What was found
SFP CLOSING ACTION FOR, RT AFT FUSELAGE 2 SCRATCHS, UPPER ONE 5 3/4 IN LENGTH & LOWER 4" LENGTH, UPPER SCRATCH HAS 1/8 DENT IN LENGTH & .224 IN DENT, MAX WIDTH 1 1/8 LOCATED BETWEEN STRINGERS 14R - 16R & FRAMES 62 & 63. MAJOR REPAIR. REPAIRED DAMAGE TO RT AFT FUSELAGE, BETWEEN FRAME 62 & 63 & STRINGERS 13R - 14R IAW SRM 53-30-01.