What was found
IMMEDIATELY FOLLOWING NR 2 ENG START, SMOKE & ELEC BURNING SMELL IN CABIN. REF ITEM NR 2 FOR TROUBLESHOOTING & DEFERRED NR 2 PACK. R & R NR 2 PACK IAW AMM 21-51-08. OPERATIONAL & LEAK CHECKED GOOD, MEL ITEM RESTORED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
IMMEDIATELY FOLLOWING NR 2 ENG START, SMOKE & ELEC BURNING SMELL IN CABIN. REF ITEM NR 2 FOR TROUBLESHOOTING & DEFERRED NR 2 PACK. R & R NR 2 PACK IAW AMM 21-51-08. OPERATIONAL & LEAK CHECKED GOOD, MEL ITEM RESTORED.