What was found
ON APPROACH TO 27L RWY, IN ICING CONDITION, WG ANTI-ICE FAIL MSG, BLEED 2 LOW TEMP, FOLLOWED BY ICE CONDITION, ANTI-ICE INOPERATIVE WARNING MSG. PERFORMED OPERATIONAL CHECK OF ANTI-ICE SYS, OPERATIONS TESTED GOOD IAW AMM 30-00-00, NO DEFECTS NOTED.