What was found
DURING MBV INSPECTION, QA FOUND 2 CRACKS ON RT REAR FUSELAGE I SKIN AT FRAME 75, BELOW STRINGER 2R. ACFT WAS REMOVED FROM SERVICE FOR MBV INSPECTION & WILL BE RETURNED TO SERVICE AFTER MBV INSPECTION. PERFORMED PERMANENT REPAIR ON CRACKS IAW ERS-EM-53MR-1898. REPAIR MATERIAL, DOUBLER 2024-T3, 0.080, FILLER 2024-T3, 0.063, ANGLE 2024-T3, 0.050, SHIM 2024-T3-0.032.