What was found
NUMBER 1 EMER FLOOR LIGHT STRIP INOPERATIVE. R & R NR 2 EMER LIGHT DC & AC INVERTER IAW AMM 33-50-11. COMPLIED WITH OPERATIONAL CHECK OF THE EMER LIGHTING SYS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NUMBER 1 EMER FLOOR LIGHT STRIP INOPERATIVE. R & R NR 2 EMER LIGHT DC & AC INVERTER IAW AMM 33-50-11. COMPLIED WITH OPERATIONAL CHECK OF THE EMER LIGHTING SYS.