What was found
BRAKE INBD INOPERATIVE MSG PRESENTED UPON GEAR EXTENSION. PERFORMED GO AROUND & COMPLETED AOM 1 PROCEDURES, NORMAL LANDING, ALL BRAKE TEMPS INDICATOR REMAINED IN THE GREEN 324M3800. FOUND INBD SOV TRIPPED, RESET INBD BRAKES OPERATIONS CHECKED OK. R & R BCU FOR PRECAUTIONARY REASONS IAW AMM CH 32-41-02. BRAKE SYS FUNCTION CHECKED OK IAW AMM CH 32-41-00.