What was found
SERVICE DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE LAMP IAW AMM 33-50-09-000-801-A & 33-50-09-400-801-A. OPS CHECK FAILED, INSPECTED AND FOUND GROUND CONNECTION FOR LAMP TO THE ASSEMBLY TO BE INADEQUATE, CLEANED AND RECONNECTED GROUND CONTACT TERMINAL IAW SWPM 20-13-21-910-802-A, SERVICE DOOR ARM LINER REMOVED AN REINSTALLED IN REFERENCE WITH EMB AMM 25-23-05-000-801-A END