What was found
SERVICE DOOR SHOWED OPEN ON MFD AND EICAS ON T/O ROLL. HIGH SPEED ABORT AT APPROXIMATELY 100 KTS. SERVICE DOOR WARNING SYS WRITTEN UP 7 TIMES SINCE 09/01. PERFORMED HIGH ENERGY STOP INSPECTION IAW AMM 05-50-16. NO DEFECTS NOTED. DEFERRED DOOR WARNING SYS, MEL 52-04 AUTH NR 090214-B. T/S SERVICE DOOR MICRO SWITCH IAW FIM 52-70-00-801-803-A SUSPECTED MICRO SWITCH S7245 BAD, R & R MICRO SWITCH IAW AMM 52-74-01-000-801-A AND 52-74-01-400-801-A, NO FIX, FOUND 2 BROKEN WIRES NEAR CONNECTOR REPAIRED IAW SWPM 20-21-00, OPC GOOD IAW AMM 52-74-01, END.