Service difficulty report · Sensor · Emb EMB145LR

Difficulty date
December 18, 2016
Submitted
December 19, 2016
Operation
Air carrier
Aircraft
N642AE
Make and model
Emb EMB145LR
Aircraft serial
145193
Aircraft time
40,037 hours, 36,001 cycles
Part
Sensor
Condition
Malfunctioned
Location
Pitot Sys
Stage of operation
NR
How discovered
9
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PITOT NR 1 INOPERATIVE EICS MESSAGE ILLUMINATED ON & OFF ON FOR ONE OR ONE OR MORE MINUTES OFF FOR 30 SECONDS. NO MESSAGE DURING GROUND OPS PITOT 1 APPEARED TO BE WORKING AS AIRSPEEDS MATCHED. REMOVED AND REPLACED STATIC PORT CURRENT SENSOR S0335 AND PITOT 1 CURRENT SENSOR K0056 IAW EMB 145 AMM 30-31-02 AND 30-31-01. OPS CHECK GOOD. REF NRWC 642-ORD-02916 FOR ALL WORK PERFORMED.