FOUND NR 2 HYD SYS BRAKE ACCUMULATOR PRESSURE GAUGE LEAKING. REMOVED AND REPLACED THE PRESSURE GAUGE IAW AMM 32-43-30. OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND NR 2 HYD SYS BRAKE ACCUMULATOR PRESSURE GAUGE LEAKING. REMOVED AND REPLACED THE PRESSURE GAUGE IAW AMM 32-43-30. OPS CHECKED GOOD.