What was found
PACK VALVE CLOSED DURING CLIMB. INSPECTED NR 1 PACK DUCKS FOR LEAKS IAW AMM 21-51-14. FOUND THREE LEAKS AND REPLACED THREE SLEEVES IAW ETN-EM-21-056 AND R & R PACK VALVE NR 1 IAW AMM 21-51-01 OPS AND LEAK CHECKED GOOD
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PACK VALVE CLOSED DURING CLIMB. INSPECTED NR 1 PACK DUCKS FOR LEAKS IAW AMM 21-51-14. FOUND THREE LEAKS AND REPLACED THREE SLEEVES IAW ETN-EM-21-056 AND R & R PACK VALVE NR 1 IAW AMM 21-51-01 OPS AND LEAK CHECKED GOOD