What was found
BLEED NR 1 OVERTEMP DURING CLIMB OUT OF 5,000FT. REMOVED AND REPLACED THE 1 ENGINE FAN AIR CONTROL THERMOSTAT IAW AMM 36-11-06. OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BLEED NR 1 OVERTEMP DURING CLIMB OUT OF 5,000FT. REMOVED AND REPLACED THE 1 ENGINE FAN AIR CONTROL THERMOSTAT IAW AMM 36-11-06. OPS CHECKED GOOD.