What was found
MAIN DOOR EXTERIOR EMERENCY LIGHT INOPERATIVE. FOUND A WIRE BROKEN AT SPLICE REMOVED AND REPLACED WIRE TERMINAL AND RECEPTICLE IAW SWPM 20-21-00. OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DOOR EXTERIOR EMERENCY LIGHT INOPERATIVE. FOUND A WIRE BROKEN AT SPLICE REMOVED AND REPLACED WIRE TERMINAL AND RECEPTICLE IAW SWPM 20-21-00. OPS CHECKED GOOD.