What was found
EMERGENCY EXIT LIGHT IN 233ALC IS INOP. UPON FURTHER INVESTIGATION FOUND ELECTRICAL CONNECTOR ABOVE MAIN DOOR REGION CEILING PANEL DISCONNECTED. RECONNECTED ELECTRICAL CONNECTOR IAW AMM 25-22-04. EMERGENCY EXIT LIGHT IN 233ALC OPERATIONAL CHECKS GOOD IAW AMM 33-50-00.