What was found
FOUND APU COWLING PROFILE 17D CRACKED APPROX 28 INCHES FROM FWD EDGE. COMPLETE:REPAIRED THE APU COWLING INTERNAL STIFFENER IAW SRM 53-32-17.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND APU COWLING PROFILE 17D CRACKED APPROX 28 INCHES FROM FWD EDGE. COMPLETE:REPAIRED THE APU COWLING INTERNAL STIFFENER IAW SRM 53-32-17.