What was found
SLIGHT ODOR OF BURNING RUBBER MORE NOTICEABLE IN CABIN, VHF 3 FAIL MESSAGE, AND RT ALT 1 FAIL MESSAGE AND REMOTE CIRCUIT BREAKER TRIP MESSAGE. REMOVED AND REPLACED CIRCUIT BREAKER CB50 ON THE LICC IAW AMM 20-35-01. OP CHECKING GOOD IAW AMM 24-42-00.