What was found
GOUGE IN THE SKIN AT FRAME 25 BETWEEN STRINGERS 21L AND 21R. CUT OUT THE DAMAGED AREA IAW SRM 53-22-01, REPAIR TYPE A, PERFORMED HFEC INSPECTION, NO DEFECTS NOTED IAW NIM 51-00-00-916-801-A00. FABRICATED A FILLER AND DOUBLER , APPLIED ALODINE AND PRIMER IAW SRM 53-22-01 51-21-01, CPM 51-21-03, AND 51-21-04. INSTALLED IAW SRM 51-21-01, AND 51-40-02, SEALED AND APPLIED TOP COAT IAW SRM 51-21-01 AND CPM 51-21-06.