What was found
CARGO DOOR LOWER BEAM HAS CORROSION. BLENDED IAW SRM 51-10-03, AND 51-10-05. FOUND TO BE OUT OF LIMITS. LOCATED, DRILLED, ALODINED, AND INSTALLED A NEW BEAM IAW SRM 51-20-03, 51-20-04, AND CPM 51-21-04.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CARGO DOOR LOWER BEAM HAS CORROSION. BLENDED IAW SRM 51-10-03, AND 51-10-05. FOUND TO BE OUT OF LIMITS. LOCATED, DRILLED, ALODINED, AND INSTALLED A NEW BEAM IAW SRM 51-20-03, 51-20-04, AND CPM 51-21-04.