What was found
CORROSION ON THE CENTER OMEGA BEAM AT FRAME 20. BLENDED THE CORROSION AND DETERMINED TO BE OUT OF LIMITS IAW SRM 53-21-10. REMOVED CENTER OMEGA BEAM. LOCATED , DRILLED AND ALODINED NEW OMEGA BEAM IAW SRM 51-20-03, AND CPM 51-21-04, INSTALLED IAW SRM 51-40-02, AND CPM 51-21-06.