What was found
BOTH EXIT EMERGENCY LIGHTS AND TWO PROXIMITY LIGHT STRIPS ARE INOPERATIVE. UPON FURTHER INSPECTION FOUND THE CONNECTOR PLUG TO NR 3 EMERGENCY POWER SUPPLY TO BE DISCONNECTED. RECONNECTED IAW AMM 33-50-04. OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BOTH EXIT EMERGENCY LIGHTS AND TWO PROXIMITY LIGHT STRIPS ARE INOPERATIVE. UPON FURTHER INSPECTION FOUND THE CONNECTOR PLUG TO NR 3 EMERGENCY POWER SUPPLY TO BE DISCONNECTED. RECONNECTED IAW AMM 33-50-04. OPS CHECKED GOOD.