What was found
RIGHT ESCAPE HATCH DAMAGED ON AFT EDGE OF FRAME. REMOVED TWO DAMAGED AFT FRAME ANGLES IAW SRM 51-40-02, FABRICATED INTERNAL FRAME ANGLE FROM 7475-T761 0.050 IAW DRAWING 145-27694-001, SRM 51-30-01, 51-20-03, CPM 51-21-04, AND 51-21-05. PERFORMED FPI OF FABRICATED INTERNAL FRAME IAW NDTM INTRODUCTION, PARA 5 D, AND ASTM E1417 TYPE 1, METHOD A SENSITY LEVEL 3, NO DEFECTS NOTED. LOCATED DRILLED , AND ALODINED A NEW EXTERNAL FRAME ANGLE IAW SRM 51-20-03, AND CPM 51-21-04. INSTALLED BOTH FRAME ANGLES IAW SRM 51-40-02. APPLIED TOPCOAT TO REPAIR AREA IAW EMB 140 CPM 51-21-06. PREPPED AND REBONDED SEAL IAW AMM 52-21-01. PERFORMED FIT CHECK IAW AMM 52-21-00-700-801-A AND 52-21-00-820-801-A. PERFORMED PRESSURIZATION LEAK CHECK IAW AMM 21-31-00-700-808-A. LEAK CHECK WITHIN LIMITS.