What was found
RT OMEGA BEAM BETWEEN FRAMES 60 AND 61 HAS TWO CRACKS MIGRATING FROM THE HOLE FOR THE NUTPLATE. REMOVED DAMAGED AREA OF OMEGA BEAM BY CUTTING IAW SRM 53-24-10. PERFORMED HFEC INSP OF CUTOUT IAW NDTM 51-00-00-916-801-A00, NO DEFECTS NOTED. FABRICATED REPAIR DOUBLER, PERFORMED FPI OF DOUBLER IAW ASTM E1417 TYPE 1, METHOD A SENSITIVITY LEVEL 3, NO DEFECTS NOTED. INSTALLED DOUBLER IAW EMB 145 SRM 53-24-10 AND 51-40-02.