What was found
NR 3 FLOOR PROXIMITY EMERGENCY LIGHT STRIP INOP. FOUND ELECTRICAL CONNECTOR ON AIRCRAFT SIDE BROKEN. REMOVED AND REPLACED CONNECTOR IAW SWPM 20-50-01. PERFORMED OPC OF EMER LIGHTS IAW AMM 33-50-00, OPC GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 3 FLOOR PROXIMITY EMERGENCY LIGHT STRIP INOP. FOUND ELECTRICAL CONNECTOR ON AIRCRAFT SIDE BROKEN. REMOVED AND REPLACED CONNECTOR IAW SWPM 20-50-01. PERFORMED OPC OF EMER LIGHTS IAW AMM 33-50-00, OPC GOOD.