What was found
FRAME 65 CARGO DOOR CUT OUT STRUCTURE CORRODED IN THE LOWER FWD CORNER. BLENDED CORROSION ON FRAME 65 , FOUND TO BE OUT OF LIMITS IAW SRM 51-10-03 AND 51-31-04. CUT OUT DAMAGED AREA IAW SRM 53-31-04, PERFORMED HFEC INSP ALONG CUT LINES IAW NDTM 51-00-00-916-801-A00, NO DEFECTS NOTED. FABRICATED DOUBLER IAW SRM 53-31-04. LOCATED, DRILLED, ALODINED AND PRIMED NEW FRAME PIECE AND DOUBLER IAW SRM 53-31-04 AND CPM 51-21-04AND 51-21-05 INSTALLED NEW FRAME PIECE AND DOUBLER IAW SRM 53-31-04 AND 51-40-02. APPLIED SURFACE PROTECTION IAW CPM 51-21-05, 51-21-06 AND ETN GN-51-017.