What was found
FRAME 68 CARGO DOOR CUT OUT STRUCTURE LOWER FWD CORNER SHEAR CLIP CORRODED. BLENDED CORRODED SHEAR CLIP, FOUND TO BE OUT OF LIMITS IAW SRM 51-10-03 AND 51-31-04. REMOVED SHEAR CLIP IAW SRM 51-40-02. LOCATED, DRILLED AND ALODINED NEW SHEAR CLIP IAW SRM 51-20-03 AND CPM 51-21-04. INSTALLED NEW SHEAR CLIP IAW SRM 51-40-02 AND APPLIED SURFACE PROTECTION IAW CPM 51-21-04, 51-21-05, 51-21-06 AND ETN GN-51-017.