What was found
CORROSION ON LATERAL L AT FRAME 68 AND CARGO DOOR THRESHOLD-C/A-APPLIED EWIS PROTECTION AT LATERAL L ANGLE AT FRAME 68 AND CARGO THRESHOLD IAW EMB SWPM 20-21-00.REMOVED FRAME 68 ANGLE T PROFILE IAW EMB 140 SRM 51-40-02. REMOVED DAMAGE SECTION OF SHEAR CLIP IAW EMB 140 SRM 53-31-04. PERFORMED HFEC INSP ALONG AREAS OF DAMAGE REMOVALIAW NDTM 51-00-00-916-801-A00. LOCATED DRILLED COUNTERSUNK AND ALODINED NEW SEGMENT OF FRAME 68 SHEAR CLIP IAW EMB 140 SRM 53-31-04 AND CPM 51-21-04. INSTALLED NEW SEGMENT OF SHEAR CLIP AT FRAME 68 IAW EMB 140 SRM 53-31-04 REINSTALLED PREVIOUSLY REMOVED FRAME 68 T PROFILE SUPPORT IAW EMB SRM 51-40-02. REMOVED EWIS PROTECTION IAW SWPM 20-21-00