What was found
CENTER OMEGA BEAM HAS EVIDENCE OF CORROSION BY THE CROSS BEAM BETWEEN FRAMES 59-60. C/A-COMPLETE:REPAIRED CENTER OMEGA BEAM AT CROSS BEAM BETWEEN FR.59-60 IAW SRM 53-24-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CENTER OMEGA BEAM HAS EVIDENCE OF CORROSION BY THE CROSS BEAM BETWEEN FRAMES 59-60. C/A-COMPLETE:REPAIRED CENTER OMEGA BEAM AT CROSS BEAM BETWEEN FR.59-60 IAW SRM 53-24-10.