As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BLD 1 LEAK IN FLIGHT QRH PROCEDURES COMPLIED WITH MESSAGE EXTINGUISHED.-C/A-INSPECTED PACK 1 FOR LOOSE DUCTING/CLAMPS. NO DEFECTS NOTED IAW EMB 145 AMM 21-20-04. FOUND #1 ENG BLEED VALVE CONNECTOR LOOSE. RESECURED CONNECTOR IAW EMB 145 AMM 36-11-05. NO DEFETCS NOTED IN #1 ENG. COMPARTMENT. RESECURED DUCT ON #1 PACK PERFORMED OPERATIONAL TEST OF BLEED SYSTEMS NO BLEED LEAK MESSAGE ON EICAS IAW AMM 21-20-01 AND 36-00-00