What was found
RT SHEAR CLEAT AT FRAME 80RT., BETWEEN STRS. 6-7 HAS A CRACK APPROX. 1/2". C/A-REMOVED AND REPLACED RT SHEAR CLEAT AT FRAME 80 BETWEEN STRINGERS 6-7 IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT SHEAR CLEAT AT FRAME 80RT., BETWEEN STRS. 6-7 HAS A CRACK APPROX. 1/2". C/A-REMOVED AND REPLACED RT SHEAR CLEAT AT FRAME 80 BETWEEN STRINGERS 6-7 IAW SRM 51-40-02.