What was found
COMPLETED MEASURING OF BLENDED SPOT NR 1 BETWEEN FRAMES 57AND 58 JUST OUTBD OF STGR 01R. AND FOUND TO BE OUT OF LIMITS IAW SRM 53-24-01. REPAIRED IAW ERS-EM-53MR-3634.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
COMPLETED MEASURING OF BLENDED SPOT NR 1 BETWEEN FRAMES 57AND 58 JUST OUTBD OF STGR 01R. AND FOUND TO BE OUT OF LIMITS IAW SRM 53-24-01. REPAIRED IAW ERS-EM-53MR-3634.