Service difficulty report · Shutoff Valve · Emb ERJ170200LR
FAA SDR system
- Difficulty date
- February 16, 2019
- Submitted
- February 18, 2019
- Operation
- Air carrier
- Make and model
- Emb ERJ170200LR
- Aircraft serial
- 17000540
- Aircraft time
- 7,564 hours, 5,187 cycles
- Part
- Shutoff Valve
- Part number
- 10012463
- Part serial
- 201500010
- Condition
- Failed
- Location
- Bleed Air Sys
- Stage of operation
- CL
- How discovered
- O
- Nature of condition
- J
- Precautionary procedure
- A
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BLEED 2 LEAK CAUTION MESSAGE DURING CLIMBOUT. BLEED 1 FAIL 2 MINUTES AFTER RECEIVING BLEED 2 LEAK MESSAGE. FAULT CODE: 36112210AM2. R&R NR 2 ENG NACELLE PRSOV IAW AMM 36-11-03, OPS CHK AND LEAK CHK GOOD. FAULT CODE: 36115002AM2 FOUND E1 FAN AIR VALVE EXHAUST DUCT DAMAGED. R&R EXHAUST DUCT IAW AMM 36-11-09, OPS CHECK AND LEAK CHECK GOOD.
More about the Emb ERJ 170-200 LR