Service difficulty report · Control Valve · Emb EMB145LR
FAA SDR system
- Difficulty date
- October 27, 2019
- Submitted
- October 28, 2019
- Operation
- Air carrier
- Aircraft
- N674RJ
- Make and model
- Emb EMB145LR
- Aircraft serial
- 14500801
- Aircraft time
- 36,938 hours, 32,836 cycles
- Part
- Control Valve
- Condition
- Leaking
- Location
- Nr 1 Bleed
- Stage of operation
- NR
- How discovered
- O
- Nature of condition
- J
- Precautionary procedure
- O
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BLD 1 LEAK WARNING MESSAGE PRESENTED W/O ENG 1 RUNNING OR BLD 1 SELECTED OPEN. OCCURED 2X @ GATE-C/A-PERFORMED #1 BLEED LEAK CHECK AS PER EMB145 AMM 36-00-00, FOUND #1 DUAL TEMP. CONTROL VALVE LEAKING. REMOVED AND REPLACED #1 DUAL TEMP CONTROL VALVE AS PER EMB145 AMM 21-60-01. OPC GOOD. LEAK CHECK GOOD.