As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BLEED 2 LEAK ENROUTE. COMPLIED WITH QRH PROCEDURES. DID NOT LAND OVERWEIGHT-C/A-FOUND LEAK ON JOINT 20 AND 22 REMOVED AND REPLACED O-RING IAW EMB 140 AMM 36-11-10. PERFORMED AIR BLEED SYSTEM ON BLEED 2 SYS ONLY IAW EMB 140 AMM 36-00-00 TASK 36-00-00-700-803-A. OPC OK.