As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STRINGER CLIP AT FRAME 80 AND STR 9R HAS A 3/8 CRACK. (EVALUATED AND FOUND SHEAR CLIP AT FRAME 80 STRINGER 9R NOT TO BE CRACKED. CRACKED SHEAR CLIP IS LOCATED AT FRAME 80 STRINGER 7R.) -C/A-REMOVED AND REPLACED SHEAR CLIP AT FRAME 7R IAW SRM 51-40-02.