As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SEVERAL EMERGENCY FLOOR PATH STRIP BAR CONNECTION FOUND BROKEN-C/A-ON FIRST AND FOURTH FLOOR PATH STRIP BAR FROM FWD WIRES CRIMPED PROPERLY WITH QUICK DICONNECT SPLICE IAW SWPM 20-50-01 ON THRIRD AND SEVENTH FLOOR PATH STRIP BAR FROM FWD WIRSE SOLDERED PEOPERLY IAW SWPM 20-30-00 REFER TO TASK CARD 33-2064 FOR THE TEST