What was found
DURING HMBV INSPECTION, QC FOUND THE FR 65 SHEAR CLIP CORRODED AT THE CARGO DOOR LWR SILL.-C/A-PERFORMED PERMANENT REPAIR TO FR 65 SHEAR CLIP AT CARGO DOOR LWR SILL IAW EMB 145 SRM 53-31-04.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HMBV INSPECTION, QC FOUND THE FR 65 SHEAR CLIP CORRODED AT THE CARGO DOOR LWR SILL.-C/A-PERFORMED PERMANENT REPAIR TO FR 65 SHEAR CLIP AT CARGO DOOR LWR SILL IAW EMB 145 SRM 53-31-04.