What was found
HYD2 LO QTY EICAS MESSAGE-C/A-FOUND E2 EDP LEAKING REMOVED AND REPLACED ENG2 ENGINE DRIVEN PUMP IAW EMB 140 AMM 29-10-03-000-801-A AND 29-10-03-400-801-A OPERATIONAL AN ENG RUNS GOOD NO LEAKS NOTED SERVICED HYD2 IAW AMM 12-13-01
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HYD2 LO QTY EICAS MESSAGE-C/A-FOUND E2 EDP LEAKING REMOVED AND REPLACED ENG2 ENGINE DRIVEN PUMP IAW EMB 140 AMM 29-10-03-000-801-A AND 29-10-03-400-801-A OPERATIONAL AN ENG RUNS GOOD NO LEAKS NOTED SERVICED HYD2 IAW AMM 12-13-01