What was found
SUPPLEMENTAL MAIN PAX ENTRY DOOR VERY HARD TO OPEN.-C/A-WHILE T/S HARD TO OPEN AND INSPECTION SUPPORT ASSY BOLTS IAW ETN-EM-52-052 FOUND DAMAGE TO THE BEARING SUPPORT AND LOCKING SHAFT MIGRATING. REF ITEM #3 THIS LOG PAGE FOR DISCREPANCIES. REMOVED AND REPLACED TUBE MOUNT/BEARING ASSY IAW ERS-EM-5200-1082. PULL TO OPEN TEST C/W IAW AMM 52-18-00. RECORED 38LBS. TEST GOOD AT THIS TIME. REMOVED AND REPLACED TUBE MOUNT/BEARING ASSY IAW ERS-EM-5200-1082. PULL TO OPEN TEST C/W IAW AMM 52-18-00. RECORED 38LBS. TEST GOOD AT THIS TIME.