Service difficulty report · Control Module · Emb EMB135KL

Difficulty date
June 28, 2020
Submitted
June 30, 2020
Operation
Air carrier
Aircraft
N808AE
Make and model
Emb EMB135KL
Aircraft serial
145519
Aircraft time
38,170 hours, 35,376 cycles
Part
Control Module
Part number
8125464
Part serial
98019631
Condition
Failed
Location
Right Temp
Stage of operation
UK
How discovered
V
Nature of condition
O
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

W/G ANTI ICE FAIL IN FLT. INSPECTED ALL DUCTS. NO BLOWN DUCTS FOUND. PREFORMED DVI OF ALL DUCTS AND SURFACES. NO BLOWN DUCTS OR DEFECTS NOTED. REMOVED AND REPLACED LH OUTLET DUCT ASSY PER EMB AMM 21-51-02. REMOVED AND REPLACED LH HEAT EXCHANGER OUTLET BOOT PER EMB AMM 21-51-02. INSPECTED PACK 1 HEAT EXCHANGER EXHAUST DUCT. NO DEFECTS NOTED IN UPPER DUCT FROM HEAT EXCHANGER. REMOVED AND INSPECTED LOWER EXHAUST DUCT AND FOUND IT TO BE CRACKED AND DEFORMED. TEMPORARILY REINSTALLED LOWER LH EXHAUST DUCT. REMOVED AND REPLACED LH EXHAUST GRATE PER EMB AMM 21-51-02, NO LEAKS NOTED AT THIS TIME. REMOVED AND REPLACED TEMPERATURE CONTROL MODULE IAW EMB140 AMM 21-60-05. OPC GOOD. REMOVED AND REPLACED PACK 1 DUCT TEMPERATURE SENSOR IAW 21-60-03. OPERATIONAL CHECK FAIL AMM 21-51-00. DID NOT FIX. REMOVED AND REPLACED PACK 1 DUCT OVERTEMPERATURE SENSOR IAW AMM 21-51-09. OPERATIONAL CHECK FAIL AMM 21-51-00-700-802-A. DID NOT FIX. REMOVED AND REPLACED TEMPERATURE CONTROL MODULE IAW EMB140 AMM 21-60-05. OPC GOOD. AMBIENT TEMPERATURE SENSOR P/N 815289-2 S/N O3084