What was found
LT FLOOR SILL HAS CORROSION AT FR32, AS MARKED. C/A COMPLETE: BLENDED AND FOUND AREAS AT LT FLOOR SILL AT FR 32 TO BE OUT OF LIMITS, IAW EMB 145 SRM 51-10-03 AND 53-22-10. R&R LT OUTBOARD SILL NR 3, IAW EMB 145 SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT FLOOR SILL HAS CORROSION AT FR32, AS MARKED. C/A COMPLETE: BLENDED AND FOUND AREAS AT LT FLOOR SILL AT FR 32 TO BE OUT OF LIMITS, IAW EMB 145 SRM 51-10-03 AND 53-22-10. R&R LT OUTBOARD SILL NR 3, IAW EMB 145 SRM 51-40-02.