What was found
CPCP ITEM , 2 EA FLOOR PNL SUPPORT ANGLES ARE CORRODED AT PAX DOOR CUTOUT BETWEEN FR 15 AND FR 18 AT STR 15 LT -C/A-REMOVED AND REPLACED 2 EA PAX DOOR FLOOR SUPPORT ANGLES BETWEEN FR15 AND FR18 STR 15L IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CPCP ITEM , 2 EA FLOOR PNL SUPPORT ANGLES ARE CORRODED AT PAX DOOR CUTOUT BETWEEN FR 15 AND FR 18 AT STR 15 LT -C/A-REMOVED AND REPLACED 2 EA PAX DOOR FLOOR SUPPORT ANGLES BETWEEN FR15 AND FR18 STR 15L IAW SRM 51-40-02.