BLEED 2 LEAK CLIMBING THROUGH APROX 8000' EXECUTED CHECKLISTS RETURNED TO DFW W/' UNDERWEIGHT LANDING DECLARED EMERGENCY-C/A-FOUND #25 BLEED SYSTEM JOINT HISSING/LEAKING. RAR 2 ORINGS IN REF TO AMM 36-11-10. LEAK CHECK GOOD.