What was found
SMOKE IN THE CABIN AND ASSOCIATED BURNING SMELL WHEN PACK 2 WAS RESET AFTER T/O FA NOTED ITSEEMED TO COME FROM CENTER OF A/C-SMOKE IN CABIN WORK SCOPE ISSUED BY REPEAT CONTROL REQUIRES CMC DOWNLOAD AND REVIEW. C/W CMC DOWNLOAD IAW MM 45-45-00 AND UPLOADED TO DATA FILES. REVIEWED DOWNLOAD & FOUND NO OTHER DESCREPANCIES. ANY MSG WAS RELATED TO ACM FAILURE. FLIGHT DECLARED EMERGENCY SMOKE IN TCABIN & ASSOCIATED BURNING SMELL WHEN PACK 2 WAS RESET AFTER T/O, FA NOTED IT SEEMED PACK 2 WAS RESET AFTER T/O FA NOTED ITSEEMED TO COME FROM CENTER OF A/C. WHILE TROUBLE SHOOTING FOUND #2 ACM SEIZED REQUIRING EO EM-2100-048 TO BE COMPLIED WITH. COMPLETED EO-EM-2100-048. R & R RH ACM REF NRWC 673-ORD-04797LEAK CHK AND OPS CHK OF ACM..