Service difficulty report · Thermal Switch · Emb EMB145LR

Difficulty date
June 19, 2021
Submitted
June 20, 2021
Operation
Air carrier
Aircraft
N605KS
Make and model
Emb EMB145LR
Aircraft serial
145059
Aircraft time
51,073 hours, 43,515 cycles
Part
Thermal Switch
Condition
Faulted
Location
Bleed System
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

BLEED 2 LEAK MESSAGE DURING CLIMB MESSAGE REMAINED DESPITE COMPLETING QRH PROCEDURE-C/A-FOLLOWED FIM TASK 36-20-00-800-802-A, DETERMINED ITS A FAULTY THERMAL SWITCH. CLEANED AFT THERMAL SWITCH BY THE AIR GROUND CONNECTION FROM LAVATORY FLUID. THERMAL SWITCH/DUCT LEAK CHECK GOOD IAW AMM 36-20-02 NO FAULTS NOTED.

More about the Emb EMB-145LR