What was found
SSI: LH CENTER FLOOR BEAM IS CORRODED JUST FWD OF SEAT TRACK AT FR 19A MAJOR REPAIR (LEVEL 2 CORROSION)-C/A-REMOVED AND INSTALLED A SERVICEABLE LH CENTER SEAT TRACK BEAM AT FR 19A IAW EMB 175 SRM 51-40-08
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SSI: LH CENTER FLOOR BEAM IS CORRODED JUST FWD OF SEAT TRACK AT FR 19A MAJOR REPAIR (LEVEL 2 CORROSION)-C/A-REMOVED AND INSTALLED A SERVICEABLE LH CENTER SEAT TRACK BEAM AT FR 19A IAW EMB 175 SRM 51-40-08