What was found
AFT GALLEY R/H AFT SLICE PLATE FLOOR STRUCTURE AT FR90 IS CORRODED.(MARKED)(LEVEL 2 CORROSION)-C/A-RAR AFT GALLEY R/H AFT SLICE PLATE FLOOR STRUCTURE AT FR90 IAW EMB-175 SRM 51-40-08, 51-21-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT GALLEY R/H AFT SLICE PLATE FLOOR STRUCTURE AT FR90 IS CORRODED.(MARKED)(LEVEL 2 CORROSION)-C/A-RAR AFT GALLEY R/H AFT SLICE PLATE FLOOR STRUCTURE AT FR90 IAW EMB-175 SRM 51-40-08, 51-21-01.