What was found
AFTER LANDING STRONG SMELL OF SMOKE IN THE CABIN. "TRANSFERRED TO NRWC 050-MIA-03003"-C/A-COMPLIED WITH MOC TRIAD WORKSCOPE. T/S PER FIM TASK 21-20-00-810-801-A. PERFORM A GVI PACK SYSTEMS 1 AND 2 IAW AMM 21-51-01., NO NOTABLE DAMAGE OR HOSES SEEN LOOSE. FURTHER T/S AND INSPECTION REQUIRED.FOLLOWING FIM 21-20-00-810-801-A FOUND TRANSITORY CONDITION OF AIR CONDITIONING PACKS. OPC OF PACK SYSTEM IAW AMM 21-51-00 OK.