What was found
FLAP FAIL MSG ON EICAS. DECLARED EMERGENCY / EQUP SWP FLT.-C/A-TROUBLESHOT FLAP FAIL MSG ON CMC IAW FIM TASK 27-51-00 CONCLUDING BLOCK DIAGRAM 3 OPS CHECK GOOD NO FURTHER DEFECTS NOTED
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLAP FAIL MSG ON EICAS. DECLARED EMERGENCY / EQUP SWP FLT.-C/A-TROUBLESHOT FLAP FAIL MSG ON CMC IAW FIM TASK 27-51-00 CONCLUDING BLOCK DIAGRAM 3 OPS CHECK GOOD NO FURTHER DEFECTS NOTED