What was found
REFERENCE DENT AND BUCKLE LOG ITEM 119: GOUGE ON INTERNAL DOUBLER OF RAT COMPARTMENT OPENING TEMP REPAIR APPLIED.(MAJOR REPAIR) -C/A-REMOVED AND REPLACED INTERNAL DOUBLER OF RAT COMPARTMENT OPENING IAW EMB 170 SRM 51-40-08.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
REFERENCE DENT AND BUCKLE LOG ITEM 119: GOUGE ON INTERNAL DOUBLER OF RAT COMPARTMENT OPENING TEMP REPAIR APPLIED.(MAJOR REPAIR) -C/A-REMOVED AND REPLACED INTERNAL DOUBLER OF RAT COMPARTMENT OPENING IAW EMB 170 SRM 51-40-08.